-1-DOC.060301-KC1300Modular Media Converter Center SystemKC-1300Operation Manual

Pagina 2

-10-Management Module SpecificationsDimension 107mm x 24mm x 86.4mmSlot position Slot 0CPU RISC-based ARM7RAM size 2M bytesFlash size 512K bytesSystem

Pagina 3

-11-Management SpecificationsManagement interfaceTelnet Via direct RS-232 console connectionTelnet Via TCP/IP Telnet softwareSNMP agent Via TCP/IP SNM

Pagina 4

-12-2. Installation2.1 UnpackingThe product package contains:• The system unit• One power cord• One 19-inch rack mounting kit• Operation Manual2.2 Sys

Pagina 5

-13-The following figure shows the model equipped with two AC power chassis.Main Chassis : provides insertion slots on front panel for CPU manage-ment

Pagina 6 - 1. Introduction

-14-2.2.2 Management ModuleThe system unit comes with one pre-installed Management module. Themodule facilitates the following functions:• Direct out

Pagina 7 - 1.1 Features

-15-Console PortThis port is a 9-pin male D-sub connector. It serves as an RS-232 DTE port.Refer to Chapter xx for the console operation. The pin defi

Pagina 8 - 1.2 Technical Specifications

-16-2.2.3 Power Chassis ModulesThe system power supply is assembled in a plug-in chassis module asshown below:Each single power module is capable to s

Pagina 9

-17-DC Power Chassis Specifications (KC1300-DC)Input power switch System power on/off switchInput power receptacle Terminal connector (screw type)Inpu

Pagina 10

-18-Removal of System Power ChassisThe system power chassis is pre-installed in the system unit when sys-tem unit is shipped from factory. The chassis

Pagina 11

-19-Insertion of System Power ChassisBefore inserting the power chassis into system unit, make sure:• The system power switch is turned off.• The powe

Pagina 12 - 2. Installation

-2-(C) 2005 KTI Networks Inc. All rights reserved. No part of this documen-tation may be reproduced in any form or by any means or used to makeany dir

Pagina 13

-20-2.2.4 Media Converter SlotsThe system chassis provides sixteen slots for installing optional slide-inMCs.A media converter can be inserted into an

Pagina 14

-21-To remove an MC from slot, the steps are:1. Disconnect all cable connections on the MC first.2. Unscrew the MC bracket from system chassis.3. Hold

Pagina 15 - Pin 6 DSR

-22-2.3 Rack MountingOne rack mounting kit is supplied in the product package. It includes two rackmounting brackets and screws for installing the sy

Pagina 16 - 2.2.3 Power Chassis Modules

-23-3. Network Management3.1 Management FunctionsThe managed converter rack system series is featured with managementfunctions and can be managed by u

Pagina 17

-24-The system unit is equipped with one management module which servesas a management agent to monitor the system status and all installedmedia conve

Pagina 18

-25-3.3 Setup for Out-of-band (Console) ManagementBefore doing any in-band management, it is necessary to perform con-sole operation for configuring I

Pagina 19

-26-2. Connect one end to the console port and connect the other end tothe PC COM port.3. Configure your PC COM port setting to match the RS-232 setti

Pagina 20

-27-3.4 Setup for In-band ManagementTo perform an in-band management, it is necessary to connect the sys-tem to your TCP/IP network. The steps are:1.

Pagina 21

-28-4. Console and Telnet OperationFunctions supported:• Set and display IP parameters for the system.• Set and display SNMP parameters for the SNMP a

Pagina 22 - 2.3 Rack Mounting

-29-* Remote MC TP link status monitoring is available only when KC-300DM in the rack is connected to a remote KC-300DM through fiberlink.Cold StartWh

Pagina 23 - 3. Network Management

-3-The information contained in this document is subject to change without priornotice. Copyright (C) KTI. All Rights Reserved.TRADEMARKSEthernet is a

Pagina 24 - 3.2 Protocols Supported

-30-Direct Console ManagementWhen you can see the self-test messages shown on screen properly, youcan press <Enter> key to start console login o

Pagina 25

-31-When login successfully, a Setup menu is shown as follows:---------------------------------------------Setup MenuTCP/IP stack for KC-1300 V1.xx[0]

Pagina 26 - Flow control : disabled

-32-4.1 IP MenuSelect [1] from Setup menu to set IP related settings.---------------------------------------------IP Menu[0] Print this menu[1] Set IP

Pagina 27

-33-4.2 SNMP MenuSelect [2] from Setup menu to perform SNMP related settings. The fol-lowing figure illustrates the SNMP menu:------------------------

Pagina 28

-34-4.3 View System StatusSelect [3] from Setup menu to view system status. The system status areshown as follows:------------------------------------

Pagina 29

-35-4.4 View Converter Slots StatusSelect [4] from setup menu to view current status of all media convertermodules in the system. The slot status are

Pagina 30

-36-The slot status definitions are:Column States InterpretationSlot 01-16 Slot position in the systemSlot #1 - slot #16 are for MCPort N/A No module

Pagina 31

-37-4.5 Restore Default ValuesSelect [5] from Setup menu to restore factory default settings.Factory default settings are:IP Address 192.168.0.2Subnet

Pagina 32 - 4.1 IP Menu

-38-4.6 Security ManagerSelect [6] from Setup menu to change login user name and password.The steps are:Display current user name---------------------

Pagina 33 - 4.2 SNMP Menu

-39-4.7 Update FirmwareSelect [7] from Setup menu to perform firmware (system software) up-grade via TFTP protocol. Before doing TFTP operation, one T

Pagina 34 - 4.3 View System Status

-4-Table of Contents1. Introduction... 61.1 Features ...

Pagina 35

-40-The steps are:Specify TFTP server IP address---------------------------------------------Enter ESC to abort.Please Input TFTP Server IP Address (x

Pagina 36

-41-5. SNMP ManagementSNMP management are performed at a network management station run-ning SNMP network management application manager software with

Pagina 37 - 4.5 Restore Default Values

-42-5.1 Configuring SNMP Settings via Console OperationBefore performing SNMP operation, proper SNMP settings must be con-figured in the system unit.

Pagina 38 - 4.6 Security Manager

-43-5.2 SNMP Private MIBUse the SNMP management application software to compile the MIB filefirst before performing any management operation. In addit

Pagina 39 - 4.7 Update Firmware

-44-5.3 SNMP TrapsThe system also supports the following SNMP traps. When the trapevent occurs, the SNMP agent will generate a trap notification to SN

Pagina 40 - 4.8 Reboot System

-45-6. Web ManagementThe system features an http server which can serve the managementrequests coming from any web browser software over internet or i

Pagina 41 - 5. SNMP Management

-46-6.2 Login to the System UnitWhen browser software connects to the system unit successfully, aLogin screen is provided for you to login to the devi

Pagina 42

-47-The following screen shows welcome screen when a successful login isperformed.In addition to the device image, the screen supports the following f

Pagina 43 - 5.2 SNMP Private MIB

-48-6.3 Converter StatusClick [Converter Status] to view all slot status in a table list.

Pagina 44 - 5.3 SNMP Traps

-49- The information includes:Column States InterpretationSlot 1-16 Slot position in the systemSlot #1 - slot #16 are for MC installationPort A Upper

Pagina 45 - 6. Web Management

-5-6.5.1 Basic ... 526.5.2 Console Port Information ...

Pagina 46 - 6.2 Login to the System Unit

-50-6.4 System StatusClick [System Status] to view system related status in a table list. Theinformation includes:Power Status : system power 1&2

Pagina 47

-51-6.5 Administrator MenuClick [Administrator] to show administrator menu. The menu includesthe following options:1. Basic : Set / View IP and SNMP r

Pagina 48 - 6.3 Converter Status

-52-6.5.1 BasicClick [Basic] to perform IP setting and SNMP settings.IP setting and SNMP setting are described in the following sectionsrespectively.

Pagina 49 - The information includes:

-53-Click [IP Address] button to set IP settings.IP settings include:IP Address : Unique IP address designated to this systemSubnet Mask : The subnet

Pagina 50 - 6.4 System Status

-54-Click [SNMP Entries] button to set SNMP settings.SNMP Entries - System optionsSNMP related settings are:Name : Logic name for the systemLocation :

Pagina 51 - 6.5 Administrator Menu

-55-SNMP Entries - Community StringsOne community contains two settings:Community name : SNMP communities to which the system belongsAccess right : Ac

Pagina 52 - 6.5.1 Basic

-56-SNMP Entries - Trap ManagersOne Trap Manager contains two settings:IP Address : IP address of the trap host to which a trap is issuedCommunity : T

Pagina 53

-57-6.5.2 Console Port InformationThis screen displays configuration of RS-232 console port.

Pagina 54

-58-6.5.3 Security ManagerSecurity Manager allows you to change login user name and password.Click [Apply] to make the changes effective.

Pagina 55

-59-6.5.4 Image Refresh TimeThe system image is updated periodically to present the latest status.The default time interval of refreshing the image is

Pagina 56

-6-1. IntroductionThe Modular Converter System KC-1300 is a managed media converter rack thatprovides 16 slots and hosts 16 units of Media Converter

Pagina 57

-60-6.5.5 Update Firmware[Update Firmware] allows you to perform firmware (system software)upgrade via TFTP protocol. Before doing TFTP operation, one

Pagina 58 - 6.5.3 Security Manager

-61-6.5.6 Reboot System[Reboot System] allows you to reboot the system unit remotely. Startingthis command will make your current http connection lost

Pagina 59 - 6.5.4 Image Refresh Time

-62-6.6 Slot Icon OperationsIn addition to the menu supported, you may click the following imageicons to show specific status.Click slot 0 on the syst

Pagina 60 - 6.5.5 Update Firmware

-63-Click any one slot in slot 1 to slot 18 to view one specific slot status.The following figure illustrates slot 9 status:Refer to section 6.3 for s

Pagina 61 - 6.5.6 Reboot System

-7-1.1 FeaturesSome of the key features include:• Managed Media Converter Center Rack• 19-inch rack-mountable 2U chassis• Managed system accommodates

Pagina 62 - 6.6 Slot Icon Operations

-8-1.2 Technical SpecificationsSystem Model KC-1300L/1A KC-1300L/2A KC-1300/1A KC-1300/2AManagement support Unmanaged Unmanaged Managed ManagedPlug-in

Pagina 63

-9-AC Power Chassis Module SpecificationsDimension 194mm x 156.6mm x 40.3mmInstallation method Plug in from system rear panelMaintenance Modular desig